GE IS200ERIOH1ACB Exciter Regulator I/O Board

د.إ8,888.00

GE IS200ERIOH1ACB Exciter Regulator I/O Board (ERIO) is a vital interface module in the EX2100 Excitation Control System, which is part of General Electric’s Mark VI Speedtronic turbine control platform.

This board manages the primary input/output signals specifically related to the exciter regulator control functions.

⚙️ Primary Function and Role

The ERIO board serves as the central I/O interface for both the system’s internal signals and the external customer signals needed to maintain precise generator excitation.

  • Signal Interface: It acts as the intermediary between the high-speed DSPX (Digital Signal Processor) controller and the various terminal boards that connect to the physical wiring.
  • Customer I/O: It processes signals coming from external terminal boards, such as:
    • EPCT (Exciter PT/CT Board): Generator voltage and current feedback.
    • ECTBG2 (Exciter Contact Terminal Board): Digital status inputs and outputs (contact I/O).
التصنيف:

الوصف

The GE IS200ERIOH1ACB Exciter Regulator I/O Board (ERIO) is a vital interface module in the EX2100 Excitation Control System, which is part of General Electric’s Mark VI Speedtronic turbine control platform.

This board manages the primary input/output signals specifically related to the exciter regulator control functions.

⚙️ Primary Function and Role

The ERIO board serves as the central I/O interface for both the system’s internal signals and the external customer signals needed to maintain precise generator excitation.

  • Signal Interface: It acts as the intermediary between the high-speed DSPX (Digital Signal Processor) controller and the various terminal boards that connect to the physical wiring.
  • Customer I/O: It processes signals coming from external terminal boards, such as:
    • EPCT (Exciter PT/CT Board): Generator voltage and current feedback.
    • ECTBG2 (Exciter Contact Terminal Board): Digital status inputs and outputs (contact I/O).
  • System I/O: It interfaces with internal system components for control and protection, including the ERDD (Exciter Regulator Dynamic Discharge) board and the EROC (Exciter Regulator Options Card).

💡 Configuration and Redundancy

The ERIO board is designed to support both basic and fault-tolerant exciter configurations:

  • Simplex (Single Controller): The ERIO board is mounted in the main Exciter Regulator Backplane (ERBP) slot.
  • Redundant (Triple Modular Redundant – TMR): In TMR systems, three ERIO boards are used (one for each controller: M1, M2, and C). These boards are attached to the ERBP (for M1) and the ERRB (Exciter Regulator Redundant Backplane) for the M2 and C controllers, ensuring continuous, fault-tolerant operation.

🛠️ Key Hardware Details

Feature Detail
Name Exciter Regulator I/O Board (ERIO)
System EX2100 Excitation Control / Mark VI
Form Factor Double-wide VME style board
Key Components Field Programmable Gate Array (FPGA), CPU sockets, toggle switch assembly, backplane connectors (P1/P2)
Indicators POWER LED, OK LED (for health), and ACTIVE LED (shows if it’s the master controller in redundant setups).

The ERIO board is crucial for regulating the generator’s field current, as it provides the regulated signals that command the power conversion bridge based on real-time generator feedback.