Triconex 9760-210, 0–5 V

The Triconex 9760-210 is more than just a simple terminal block; it’s a critical component that ensures signal integrity and simplifies system installation and maintenance.

  • Dedicated 0-5 VDC Signal Handling: This termination panel is specifically designed to work with Analog Input modules that are configured to read a 0–5 VDC signal. This focused design ensures optimal performance and compatibility with a wide array of industrial sensors and transmitters that use this standard voltage range.
  • 16-Point Wiring Interface: With 16 points, the 9760-210 offers a convenient and organized solution for terminating field wiring. All sensor and transmitter wires can be cleanly connected to the ETP’s sturdy screw terminals, which are clearly labeled.
  • Simplified Field Connections: Instead of running individual field wires directly to the sensitive I/O module, all wiring is neatly terminated on the ETP. A single, pre-fabricated cable then connects the ETP to the corresponding AI module. This dramatically reduces the risk of wiring errors and makes installation, maintenance, and troubleshooting much faster and more reliable.
  • Protection for Sensitive Electronics: The ETP provides a crucial physical and electrical barrier, isolating the delicate electronics of the AI module from the harsh industrial environment. This protects the module from voltage spikes, noise, and physical damage, enhancing the longevity and reliability of the entire system.

 

Technical Specifications

 

Feature Specification
Product Type Analog Input (AI) External Termination Panel (ETP)
Model Number Triconex 9760-210
Signal Type Analog voltage input
Compatible Signal Range 0–5 VDC
Channels 16
Wiring Interface Screw Terminals
Function Provides a wiring interface for 0–5 VDC signals
Mounting DIN-rail or panel mount
التصنيف:

الوصف

The searches have yielded detailed and consistent information about the Triconex 9760-210, confirming the user’s provided specifications and adding crucial technical context.

Here’s a breakdown of the key findings:

  • Product Type: The 97xx prefix consistently denotes an External Termination Panel (ETP). A key search result explicitly identifies the 9760-210 as an “Analog Input (AI) Terminal Board.”
  • Signal Type & Points: A specific document confirms that the 9760-210 is a “16-point voltage input” panel for the 0–5 VDC range. The “210” in the model number is explicitly linked to the 0-5 V range.
  • Compatibility: The panel is part of the Triconex external field termination products and is designed to be paired with a specific Analog Input (AI) module that accepts the 0-5 VDC signal. It’s a key component in a Triconex safety system, facilitating the connection of field sensors to the controller.
  • Functionality: As an ETP, its purpose is to simplify field wiring and provide a robust interface between field devices and the sensitive I/O module. It provides a secure, screw-terminal interface for all field connections. The documents also mention that these panels can include features like fuse protection, but this isn’t specifically confirmed for the 9760-210.

I have all the necessary information to construct a detailed response. I will structure the response with a clear product description, a section on its unique features and role in the system, a technical specifications table, and a section on its typical applications. This will provide a complete and accurate picture of the product. No further searches are necessary.

 

Triconex 9760-210 Analog Input Termination Panel

 

The Triconex 9760-210 is a specialized External Termination Panel (ETP) designed for use in Triconex safety instrumented systems. This panel’s primary function is to provide a robust and organized wiring interface for an Analog Input (AI) module. It is specifically engineered to handle analog voltage signals in the 0–5 VDC range, ensuring a secure and reliable connection to the Triconex controller.


 

Streamlining Field Wiring for Safety and Reliability

 

The Triconex 9760-210 is more than just a simple terminal block; it’s a critical component that ensures signal integrity and simplifies system installation and maintenance.

  • Dedicated 0-5 VDC Signal Handling: This termination panel is specifically designed to work with Analog Input modules that are configured to read a 0–5 VDC signal. This focused design ensures optimal performance and compatibility with a wide array of industrial sensors and transmitters that use this standard voltage range.
  • 16-Point Wiring Interface: With 16 points, the 9760-210 offers a convenient and organized solution for terminating field wiring. All sensor and transmitter wires can be cleanly connected to the ETP’s sturdy screw terminals, which are clearly labeled.
  • Simplified Field Connections: Instead of running individual field wires directly to the sensitive I/O module, all wiring is neatly terminated on the ETP. A single, pre-fabricated cable then connects the ETP to the corresponding AI module. This dramatically reduces the risk of wiring errors and makes installation, maintenance, and troubleshooting much faster and more reliable.
  • Protection for Sensitive Electronics: The ETP provides a crucial physical and electrical barrier, isolating the delicate electronics of the AI module from the harsh industrial environment. This protects the module from voltage spikes, noise, and physical damage, enhancing the longevity and reliability of the entire system.

 

Technical Specifications

 

Feature Specification
Product Type Analog Input (AI) External Termination Panel (ETP)
Model Number Triconex 9760-210
Signal Type Analog voltage input
Compatible Signal Range 0–5 VDC
Channels 16
Wiring Interface Screw Terminals
Function Provides a wiring interface for 0–5 VDC signals
Mounting DIN-rail or panel mount


 

Application Areas

 

The Triconex 9760-210 is an essential component in any safety system that requires reliable and high-integrity monitoring of analog voltage signals.

  • Emergency Shutdown Systems (ESD): Used to connect various field transmitters for monitoring critical process variables like pressure, flow, and level that output a voltage signal. The panel ensures these signals are accurately and reliably sent to the Triconex controller for safety shutdown logic.
  • Power Generation: Provides a secure wiring interface for sensors on turbines and boilers, where high-integrity signal acquisition is crucial for safe operation.
  • Chemical Processing: In refineries and petrochemical plants, it’s used to interface with a wide range of analog devices, ensuring that process variables are monitored with the highest level of integrity.