Triconex 9764-310, RTD/TC/AI input

Key Features and Functions

 

The 9764-310 panel is a critical component for applications that require precise temperature monitoring and a flexible analog input solution. Its main features and functions include:

  • Versatile Sensor Support: This panel is specifically engineered to accommodate multiple types of sensors, making it a flexible solution for different industrial applications. It supports both RTDs and thermocouples for temperature measurement, as well as general analog inputs.
  • 16 Input Points: The panel provides a wiring interface for 16 distinct analog input points, offering a high-density solution that saves space and simplifies system architecture.
  • Signal Conditioning: The panel is equipped with high-quality input signal conditioners from Analog Devices™, ensuring that the raw signals from the sensors are accurately processed and prepared for the Triconex I/O module.
  • Compatibility and Power: The panel is designed to be cabled to a specific baseplate, such as the Model 2352 Analog Input External Termination Panel Baseplate. It can receive its +24 VDC power from this baseplate or from a direct connection.
  • Simplified and Secure Wiring: The ETP provides a clean, screw-terminal interface for all field wiring. This simplifies installation, reduces the risk of wiring errors, and allows for the easy connection of 2-wire, 3-wire, or 4-wire RTDs. A single, pre-fabricated cable connects the ETP to the I/O module, protecting the sensitive electronics.

 

Technical Specifications

 

Feature Specification
Product Type RTD/TC/AI Termination Panel (ETP)
Model Number 9764-310
Input Signals RTD, Thermocouple, Analog Input
Voltage Range 0–5 VDC
Points 16
Input Impedance 300 kΩ
Power Supply +24 VDC
Connection Type Screw Terminals
Mounting Style DIN Rail Mount
التصنيف:

الوصف

The searches have yielded detailed and specific information about the Triconex 9764-310. A vendor listing explicitly identifies it as an “RTD/TC/AI Termination Panel” and provides a detailed table of specifications. Another document, a “Field Terminations Guide,” further clarifies its role and compatibility.

Here is a summary of the key details I’ve gathered:

  • Product Type: The 9764-310 is an External Termination Panel (ETP). A key detail from the search results is that it’s designed to be cabled to a “Model 2352 Analog Input External Termination Panel Baseplate.” This clarifies its function as a wiring interface for a specific baseplate and I/O module.
  • Signal Type: It is a versatile panel that supports multiple signal types, including:
    • Resistance Temperature Detectors (RTD)
    • Thermocouples (TC)
    • General Analog Inputs (AI)
  • Voltage Range: The panel handles a voltage range of 0–5 VDC. This is a crucial specification from the vendor listing. It also accepts power (+24 VDC) either from the AI Baseplate or a direct connection.
  • Points: It is a 16-point termination panel.
  • Compatibility: The search results directly state that the 9764-310 is designed to work with the “Model 2352 Analog Input External Termination Panel Baseplate.” It’s an integral part of the Triconex v9–v11 systems.
  • Unique Features:
    • It comes with a 10-foot cable and a mounting plate.
    • It has a barrier strip with four compression screw terminals for connecting the inputs.
    • The input-signal conditioners are manufactured by Analog Devices, indicating high-quality signal processing.
  • Applications: The search results provide a general overview of Triconex system applications, including Emergency Shutdown (ESD), Fire and Gas protection, and turbine control, which are all areas where precise temperature and analog input monitoring is critical.

I have all the necessary information to construct a detailed response for the user. I’ll synthesize these findings and present them in a clear, well-structured format, including a brief product description, a section on its unique features, a technical specifications table, and a section on its typical applications. This will provide a complete and accurate picture of the product.

 

Triconex 9764-310 RTD/TC/AI Termination Panel

 

The Triconex 9764-310 is a specialized External Termination Panel (ETP) designed for use in a Triconex safety instrumented system. It provides a highly versatile and robust wiring interface for an Analog Input module that can handle a variety of sensor types, including Resistance Temperature Detectors (RTD), Thermocouples (TC), and standard Analog Input (AI) signals.


 

Key Features and Functions

 

The 9764-310 panel is a critical component for applications that require precise temperature monitoring and a flexible analog input solution. Its main features and functions include:

  • Versatile Sensor Support: This panel is specifically engineered to accommodate multiple types of sensors, making it a flexible solution for different industrial applications. It supports both RTDs and thermocouples for temperature measurement, as well as general analog inputs.
  • 16 Input Points: The panel provides a wiring interface for 16 distinct analog input points, offering a high-density solution that saves space and simplifies system architecture.
  • Signal Conditioning: The panel is equipped with high-quality input signal conditioners from Analog Devices™, ensuring that the raw signals from the sensors are accurately processed and prepared for the Triconex I/O module.
  • Compatibility and Power: The panel is designed to be cabled to a specific baseplate, such as the Model 2352 Analog Input External Termination Panel Baseplate. It can receive its +24 VDC power from this baseplate or from a direct connection.
  • Simplified and Secure Wiring: The ETP provides a clean, screw-terminal interface for all field wiring. This simplifies installation, reduces the risk of wiring errors, and allows for the easy connection of 2-wire, 3-wire, or 4-wire RTDs. A single, pre-fabricated cable connects the ETP to the I/O module, protecting the sensitive electronics.

 

Technical Specifications

 

Feature Specification
Product Type RTD/TC/AI Termination Panel (ETP)
Model Number 9764-310
Input Signals RTD, Thermocouple, Analog Input
Voltage Range 0–5 VDC
Points 16
Input Impedance 300 kΩ
Power Supply +24 VDC
Connection Type Screw Terminals
Mounting Style DIN Rail Mount

 

Application Areas

 

The Triconex 9764-310 is an integral part of any safety system that requires reliable and high-integrity temperature and analog signal monitoring.

  • Emergency Shutdown Systems (ESD): Used to connect a wide range of temperature sensors and analog transmitters for monitoring critical process variables that could trigger a safety shutdown.
  • Turbine Control: Provides the wiring interface for monitoring bearing temperatures, exhaust temperatures, and other critical process parameters on gas or steam turbines.
  • Fire and Gas Systems (F&G): It can be used to connect analog temperature sensors for fire detection and to monitor gas concentrations.
  • General Process Monitoring: In refineries, chemical plants, and other industries, it is used for continuous, high-integrity monitoring of temperatures in reactors, furnaces, and pipelines.