WOODWARD 8200-1343

Technical Specifications (Typical for Flex500 8200-1343)

 

Parameter Value
Product Type Industrial Control Platform / Digital Controller
Manufacturer Woodward
Series Flex500
Part Number 8200-1343
Mounting Front Panel Mount (Housing suitable for door mounting)
Power Supply LVDC (Low-Voltage Direct Current), 18–36 VDC
Operator Interface Integrated Operator Control Panel (OCP)
Programming Software Woodward GAP™ (Graphical Application Program)
Compatible I/O Woodward CAN-based Distributed I/O Modules (RTCNet/Linknet-HT)
Communication Ports Ethernet, CAN, RS-232, RS-485 (typical for Flex500 series)
Compliance Standard & Marine Compliance (often a variant option for this model)
Operating Temperature -20°C to +70°C (typical for Flex500)
Applications Steam Turbines, Gas Turbines, Engines, Compressors
التصنيف:

الوصف

As an industrial automation expert, the WOODWARD 8200-1343 is a specific part number for a Woodward Flex500 industrial control platform. This unit is a versatile and powerful digital controller designed for critical applications involving steam turbines, gas turbines, engines, or compressors.

The breakdown of the part number and associated information reveals its key characteristics:

  • 8200-1343: This is the specific part number for a particular configuration of the Flex500.
  • Flex500: This is the product family. The Flex500 is a highly flexible control platform that can be customized with Woodward’s Graphical Application Program (GAP™) software.
  • Front Panel Mount: The “8200-1343” specifically indicates that this unit is designed for front panel mounting. This means it can be directly mounted onto the door or front of a control cabinet, making its Operator Control Panel (OCP) and connections easily accessible.
  • LVDC (Low-Voltage Direct Current): This specifies the power supply requirement. The unit operates on a low-voltage DC input, typically in the range of 18–36 VDC.
  • OCP (Operator Control Panel): This unit includes an integrated Operator Control Panel (OCP). This means it has a built-in display and keypad, allowing for direct user interaction, local control, monitoring, and diagnostics without needing an external HMI in all cases.
  • Application Flexibility: While the Flex500 platform is broadly applicable, this specific model (8200-1343) comes without application software pre-installed. This allows engineers to custom program it using Woodward’s GAP™ software for a wide range of specific control algorithms, such as compressor anti-surge, steam turbine control, gas turbine control, and engine control.
  • Communication: It’s compatible with Woodward’s CAN-based distributed I/O Modules (RTCNet/Linknet-HT) and typically features Ethernet, CAN, RS-232, and RS-485 communication interfaces.

 

Key Features and Benefits

 

  • Integrated Control Platform: A single, powerful controller for complex machinery like turbines and engines.
  • Customizable Logic: Programmed using Woodward’s GAP™ software, offering extensive flexibility to adapt to specific application requirements.
  • Front Panel Mounting with OCP: Simplifies installation and provides convenient local control and monitoring capabilities directly on the cabinet door.
  • Low-Voltage DC Power: Suitable for systems where LVDC power is preferred or readily available.
  • Distributed I/O Support: Compatible with Woodward’s CAN-based distributed I/O modules, allowing for flexible system expansion and reduced wiring complexity.
  • Robust and Industrial-Grade: Designed to operate reliably in demanding industrial environments, ensuring stability and long-term performance.
  • Comprehensive Communication: Multiple communication ports enable seamless integration with other control systems, HMIs, and plant networks.
  • Diagnostic Capabilities: The OCP and communication interfaces facilitate effective troubleshooting and system diagnostics.

 

Technical Specifications (Typical for Flex500 8200-1343)

 

Parameter Value
Product Type Industrial Control Platform / Digital Controller
Manufacturer Woodward
Series Flex500
Part Number 8200-1343
Mounting Front Panel Mount (Housing suitable for door mounting)
Power Supply LVDC (Low-Voltage Direct Current), 18–36 VDC
Operator Interface Integrated Operator Control Panel (OCP)
Programming Software Woodward GAP™ (Graphical Application Program)
Compatible I/O Woodward CAN-based Distributed I/O Modules (RTCNet/Linknet-HT)
Communication Ports Ethernet, CAN, RS-232, RS-485 (typical for Flex500 series)
Compliance Standard & Marine Compliance (often a variant option for this model)
Operating Temperature -20°C to +70°C (typical for Flex500)
Applications Steam Turbines, Gas Turbines, Engines, Compressors


 

Typical Applications

 

The WOODWARD Flex500 8200-1343 is primarily used in the industrial energy sector for precise and reliable control and protection of critical rotating machinery.

  • Power Generation: Controlling gas turbines and steam turbines in power plants, industrial co-generation facilities, and renewable energy systems.
  • Oil and Gas: Managing compressors, pumps, and other large rotating equipment in refineries, pipelines, and processing plants.
  • Marine Propulsion and Power: Providing robust control for marine diesel engines and associated power generation systems.
  • General Industrial Applications: Any industrial setup requiring sophisticated control and protection of engines or turbine-driven machinery.

 

Related Products and Solutions

 

To create a complete control system with the WOODWARD Flex500 8200-1343, you’d typically integrate it with:

  • Woodward GAP™ Software: For custom programming and configuration of the controller.
  • Woodward Distributed I/O Modules (RTCNet/Linknet-HT): To expand input/output capabilities for various sensors and actuators.
  • Sensors and Transducers: For measuring parameters like speed, temperature, pressure, and vibration.
  • Actuators and Valves: Such as Woodward governors and fuel valves, controlled by the Flex500 to regulate machinery operation.
  • HMIs (Human-Machine Interfaces) / SCADA Systems: For supervisory control, data visualization, and advanced alarm management. While the OCP provides local interaction, a larger HMI is often used for overall plant control.
  • Woodward Netsim Software: For simulation and testing of the control logic on a PC before deployment.